Microstructured Semiconductor Neutron Detector (MSND)

The MSND is a core technology developed as an alternative to He-3 for thermal neutron detection. MSNDs can be configured in custom or RDT standard configurations (e.g. Domino) to provide compact, high efficiency neutron detectors that maximize SWAP-C parameters. Detector’s based on MSND technology can be implemented in handheld, wearable, stationary, and mobile detection systems.

MSND and Quarter Size Comparison Close up Image

Features

  • Surface mount ceramic package
  • Silver-plated RF integrated shielding
  • Thin form factor
  • Dimensions: 12.6 x 12.6 x 2.4 mm
  • 20-30% thermal neutron efficiency
  • Low power operation
  • Low voltage operation
  • Solid-state semiconductor device
  • 1-cm2 active area

Microstructured Semiconductor Neutron Detector Performance

One of the key components to advancing the neutron detection efficiency and increased counting efficiency, is the recent advances in high-aspect ratio deep etching techniques of a common thin-film semiconductor diode neutron detector (MSND). Neutron detector applications include those for homeland security (e.g., border screening), fundamental research (e.g., neutron scattering beamlines), and industrial monitoring (e.g., personnel monitoring, water content in soil). Solid-State neutron detectors provide an alternative to the He-3 based neutron detectors, maintaining a high thermal-neutron detection efficiency, at a fraction of the volume, mass, voltage, and power required from gas or liquid detectors.

simulated MSND Neutron Response graph

Solid-State Neutron Detection Applications: homeland security (e.g., border screening), fundamental research (e.g., neutron scattering beamlines), and industrial monitoring (e.g., personnel monitoring, water content in soil). They provide an alternative to the 3He-based detectors, maintaining a high thermal-neutron detection efficiency, at a fraction of the volume, mass, voltage, and power required from gas or liquid detectors. Recommend AC coupling to electronic readout circuit.

The MSND® technology implements Li-6 conversion to yield a thermal neutron detection efficiency of 30%. Optimum HDPE moderator for Cf-252 neutron source at 1-m is 3-4 cm in front and 3-6 cm behind the MSND® sensor. Recommend AC coupling to electronic readout circuit.

Microstructured Semiconductor Neutron Detector (MSND) Graph

Products That Use The MSND

Applications

The radiation detection industry has grown over the past 50 years, due to the progression of understanding and uses of radiation in both academics and industry; with the last decade inviting concerns of improved and continued homeland security and responses to industrial accidents such as the Fukushima meltdown.  In response to this growth, RDT has developed MSND® technology that can be used for numerous applications in numerous industries.

Homeland Security & Defense

Border Screening

Fundamental Research

Neutron Scattering Beam Lines

Healthcare

Neutron Cancer Therapy

Industrial Monitoring

Personnel Monitoring, Water Content In Soil

Carbon-Based & Alternative Energy

Exploratory Fossil Fuel Drivers

Our Distributor

RDT Markets and Distributes All RDT Developed Technologies, Excluding: 

–  MSND®  Technology

Distributors for MSND®  Technologies Are Listed Below:

Rotunda Logo

Rotunda Scientific Technologies, LLC

3732 Fishcreek Road Suite #913, Stow, OH 44224 USA

Tel +1 (330) 906-3403 Fax +1 (330) 294-0078

Info@rotundascitech.com

Exclusive Territories:

U.S.A & the Americas, Asia, Europe, Africa, Australia, New Zealand, Oceania